Stationary oxyacetylene welding equipment is installed where welding operations are conducted in a fixed location. Oxygen and acetylene are provided in the welding area as outlined below.

Oxygen. Oxygen is obtained from a number of cylinders manifolded and equipped with a master regulator. The regulator and manifold control the pressure and the flow together (fig. 5-1). The oxygen is supplied to the welding stations through a pipe line equipped with station outlets (fig. 5-2).

Stationary oxygen cylinder manifold and other equipment.

Station outlet for oxygen or acetylene.
Acetylene. Acetylene is obtained either from acetylene cylinders set up as shown in figure 5-3, or an acetylene generator (fig. 5-4). The acetylene is supplied to the welding stations through a pipe line equipped with station outlets as shown in figure 5-2.

Stationary Oxyacetylene Welding Equipment

acetylene generator and operating equipment